c-mac.gif (1316 bytes)  pulse continuity timer RT40

Universal pulse continuity module
   Automatic start or start at first pulse
   With or without latch function
16 time ranges/combinations in one unit
Inputs for many sensor types
1-pole relay output
DC supply or AC supplies up to 230 VAC
Made in accordance with the CE and EMC regulations

rt40.jpg (8271 bytes)

The unit is used for speed monitoring, where the output relay is activated, if the unit receives input pulses with an interval, which is shorter than the selected time.
By means of a rotary switch on top of the module you can select between 3 different functions and 4 time ranges.
The module is available in 4 supply voltage and 3 time range variants, see specifications and table.

download datasheet (PDF-format)

Standard supply voltages:
24 V AC/DC
24 VDC
115 VAC
230 VAC
other ranges upon request

Standard time ranges:
Version M1:
0.06 - 2.5 sec.
0.25 - 10 sec.
2 - 80 sec.
10 - 640 sec.
Version M2:
0.4 - 15 sec.
1.5 - 60 sec.
0.2 - 8 min.
1.6 - 64 min.
Version M3
0.06 - 2.5 min.
0.25 - 10 min.
2 - 80 min.
10 - 640 min.

Specifications RT40.

Connections,
NPN/PNP sensor:

rt-til11.gif (4553 bytes)

Connections,
Namur sensor:

rt-til12.gif (4375 bytes)

Connections,
contact:

rt-til13.gif (4518 bytes)

Functional diagram: